Test Catalog

Test Id : PCPS

Phencyclidine Confirmation, Serum

Test Catalog

Useful For
Suggests clinical disorders or settings where the test may be helpful

Confirming drug exposure involving the stimulant phencyclidine

Method Name
A short description of the method used to perform the test

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

Phencyclidine Confirmation, S

Aliases
Lists additional common names for a test, as an aid in searching

Angel Dust

Rocket Fuel

Specimen Type
Describes the specimen type validated for testing

Serum Red

Ordering Guidance

Additional drug panels and specific requests are available; call 800-533-1710.

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: Red top (Serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL Serum

Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.

Special Instructions
Library of PDFs including pertinent information and forms related to the test

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

Serum: 0.5 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
Serum Red Refrigerated (preferred) 28 days
Ambient 48 hours
Frozen 28 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

Confirming drug exposure involving the stimulant phencyclidine

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Phencyclidine (PCP) affects diverse neural pathways and interacts with cholinergic, adrenergic, gamma-aminobutyric acid (GABA) secreting, and serotoninergic receptors, as well as opiate neuronal receptors and gamma receptors while its principle psychoactive effects are thought to come from its inhibitory effects on the N-methyl-D-aspartate (NMDA) receptor. It has analgesic, anesthetic, and stimulatory effects, giving bizarre behavior, ranging from depression through catatonia, euphoria, violent rage, and hallucinations. Most fatalities result from its hypertensive effect.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Negative

Positive results are reported with a quantitative result.

 

Cutoff concentrations:

Phencyclidine: 1.0 ng/mL

Interpretation
Provides information to assist in interpretation of the test results

This test will identify patients who have taken phencyclidine.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

Specimens collected in serum gel tubes are not acceptable because the drug can absorb onto the gel and lead to falsely decreased concentrations.

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Langman LJ, Bechtel LK, Holstege CP. Clinical toxicology. In: Rifai N, Chiu RWK, Young I, Burnham CAD, Wittwer CT, eds. Tietz Textbook of Laboratory Medicine. 7th ed. Elsevier; 2023:chap 43

2. Baselt RC. Disposition of Toxic Drugs and Chemical in Man. 12th ed. Biomedical Publications; 2020

Method Description
Describes how the test is performed and provides a method-specific reference

The sample is extracted through protein precipitation, diluted, and then analyzed by liquid chromatography tandem mass spectrometry for the presence of phencyclidine.(Unpublished Mayo method)

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Thursday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

3 to 9 days

Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Mayo Clinic Laboratories - Rochester Superior Drive
CLIA Number: 24D1040592

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

G0480

83992 (if appropriate for select payers)

Clinical Toxicology CPT Code Client Guidance

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
PCPS Phencyclidine Confirmation, S 3934-7
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
624110 Phencyclidine 3934-7

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

No Sample Reports Available

Test Update Resources

Change Type Effective Date
New Test 2026-09-28