Useful For
Suggests clinical disorders or settings where the test may be helpful

Genomic profiling of suspected primary brain tumors or brain or leptomeningeal metastases for predicting prognosis and identifying matched targeted therapies or emerging resistance mechanisms

 

This test is not useful for prenatal screening.

Genetics Test Information
Provides information that may help with selection of the correct genetic test or proper submission of the test request

This test uses amplicon-based next-generation sequencing (NGS) to determine single nucleotide variants (SNVs, including cis-trans), deletions and insertions (delins), copy number variations (CNVs), and microsatellite instability (MSI). Circulating tumor DNA (ctDNA) is used to detect somatic (ie, tumor specific) mutations in 81 genes.

 

Note: This test is performed to evaluate for somatic (ie, tumor-specific) mutations. Although germline (ie, inherited) alterations may be detected, this test cannot distinguish between germline variants and somatic mutations with absolute certainty.

Highlights

LiquidHALLMARK CSF is a sensitive next-generation sequencing assay that targets circulating tumor DNA in cerebrospinal fluid (CSF) in patients with suspected brain or leptomeningeal metastases. It can detect driver mutations and emerging mutations of therapeutic resistance to inform physicians of the appropriate targeted treatment selection.

Method Name
A short description of the method used to perform the test

Amplicon-Based Next-Generation Sequencing

NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test

LiquidHALLMARK CSF

Aliases
Lists additional common names for a test, as an aid in searching

Cancer NGS Panel

Cancer Panel

Cell free DNA

cfDNA

Circulating tumor DNA

CNV

Comprehensive Genomic Profiling

Copy number variant

ctDNA

Gene amplification

Large Cancer Panel

Large Somatic NGS Cancer Panel

Liquid biopsy

Liquid biopsy panel

Lucence

Microsatellite Instability

MSI

Next Gen Sequencing

Next Generation Sequencing Test

NGS

Oncology panel

Sequence variant

Single nucleotide variant

Splice variant

Specimen Type
Describes the specimen type validated for testing

CSF

Shipping Instructions

Freeze the specimen immediately following collection. It is critical that the specimen remains frozen throughout the shipping process and is never thawed.

 

The collected specimen is stable for up to 30 days if stored frozen at the collection site.

Necessary Information

1. Order questions are required for testing to proceed.

If not ordering electronically, submit LiquidHALLMARK Patient Information with the specimen.

2. A pathology report is recommended. Testing may proceed without this information; however, it aids in providing a more thorough and accurate interpretation of results. Ordering healthcare professionals are strongly encouraged to provide the information and send it with the specimen.

ORDER QUESTIONS AND ANSWERS

Question ID Description Answers
LUC31 Original Diagnosis Date
LUC32 Diagnosis Lung
Breast
Pancreas
Colon
Prostate
Ovarian
CNS
Other
Not Specified
LUC33 Subtype If Applicable
LUC34 Disease Stage Advanced Cancer
Other
Not Specified
LUC35 Current Therapy and Response
LUC36 Disease Status Localized
Metastatic
Refractory
Progression
Recurrent
Relapse
Other
Not Specified
LUC37 ICD-10 Codes

Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Supplies: Sterile Specimen Tube, 6 mL (T485)

Container/Tube: Sterile tube

Specimen Volume: 5 mL

Collection Instructions:

1. Perform lumbar puncture and discard the first 1 mL to 2 mL of cerebrospinal fluid (CSF).

2. Collect CSF directly into a sterile tube.

3. Inspect specimen for visible discoloration. Specimen must be clear and colorless to perform testing.

4. Freeze sample upright prior to placing in transport container.

5. Send frozen.

Forms

If not ordering electronically, complete, print, and send a LiquidHALLMARK Patient Information with the specimen.

Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.

1 mL

Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis Reject

Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen Type Temperature Time Special Container
CSF Frozen 30 days

Useful For
Suggests clinical disorders or settings where the test may be helpful

Genomic profiling of suspected primary brain tumors or brain or leptomeningeal metastases for predicting prognosis and identifying matched targeted therapies or emerging resistance mechanisms

 

This test is not useful for prenatal screening.

Genetics Test Information
Provides information that may help with selection of the correct genetic test or proper submission of the test request

This test uses amplicon-based next-generation sequencing (NGS) to determine single nucleotide variants (SNVs, including cis-trans), deletions and insertions (delins), copy number variations (CNVs), and microsatellite instability (MSI). Circulating tumor DNA (ctDNA) is used to detect somatic (ie, tumor specific) mutations in 81 genes.

 

Note: This test is performed to evaluate for somatic (ie, tumor-specific) mutations. Although germline (ie, inherited) alterations may be detected, this test cannot distinguish between germline variants and somatic mutations with absolute certainty.

Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

LiquidHALLMARK CSF enables genomic profiling of cerebrospinal fluid (CSF) cell-free DNA to detect clinically relevant and actionable alterations associated with FDA-approved and emerging therapies, including key biomarkers such as EGFR, BRAF, KRAS, ERBB2, and H3 (histone) gene mutations, as well as other guideline-recommended targets.

 

In patients with suspected or confirmed CNS or leptomeningeal metastases, CSF-based analysis can complement tissue and plasma testing by improving detection of tumor-derived alterations within the central nervous system. Results may support therapy selection and provide insight into molecular evolution and treatment response over time.

 

This test is intended as an adjunct to standard diagnostic approaches and is not a substitute for primary diagnosis.

Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

An interpretive report will be provided

Interpretation
Provides information to assist in interpretation of the test results

The interpretation of molecular biomarker analysis includes an overview of the results and the associated prognostic and therapeutic implications.

Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

This report reflects the analysis of DNA from an extracted nucleic acid sample, and in very rare cases (for example, bone marrow transplant or recent blood transfusion) the analyzed DNA may not reflect the patient’s genome, leading possibly to false negative and/or false positive results. Nucleic acid studies do not constitute a definitive test for the selected conditions in all individuals.

 

This circulating tumor (ct) DNA test is clinically validated for CSF specimens only.

 

It should be realized that there are possible sources of error. Errors can result from trace contamination, rare technical errors, rare genetic variants that interfere with analysis, recent scientific developments, and alternative classification systems.

 

Test sensitivity may be altered based on factors such as excessive cell lysis before processing, sampling during treatment, tissue heterogeneity, and the relative yield of circulating nucleic acids from sample.

 

Sensitivity of this test has been determined for the test methodology for a set of variants that do not necessarily include those identified in the report. Sensitivity and specificity data for all variants reported are not available. Where reported allele frequencies fall below 0.1% (single nucleotide variations/deletions-insertions), absolute number of variant reads supporting the call are considered, but specificity data is not available on this. Deletions or insertions involving more than 30 base pairs may not be reliably detected by the sequencing methodology. Although most of the intended targeted regions are sequenced in their entirety, some regions may be incompletely covered due to technical limitations. Therefore, absence of a detected variant in these regions and in regions not covered by this test does not exclude the presence of a disease-causing variant. Intronic variants and synonymous substitutions are not reported unless previously documented as clinically significant. Variants classified as benign or likely benign in ClinVar and/or variants with population allele frequency (in external or internal databases) of greater than 1% (non-founder mutations) are not reported.

 

This test is not intended for and cannot confirm germline status in any manner. Variants detected may be of tumor-derived somatic, germline, or non-tumor somatic origins, including mosaicism, clonal hematopoiesis of indeterminate potential (CHIP). Genes with alterations that may be derived from CHIP include, but are not limited to, ASXL1, ATM, CBL, DNMT3A, JAK2, MPL, MYD88, SF3B1, TET2, TP53, and U2AF1. Clinical correlation is recommended. Genetic counseling may be considered if deemed appropriate clinically.

 

The absence of ctDNA findings may correlate with low systemic disease volume or disease that is being effectively treated. It is also possible that there are genomic alterations in targets not included in the panel or others not detectable by this analysis due to inherent analytical limitations.

 

This test should be one of many aspects used by the treating healthcare professional to help with a diagnosis and treatment plan, but it is not a diagnosis itself. Clinical diagnosis provided by the treating healthcare professional is used to determine the relevant indication for determining appropriate clinical actionability/evidence and matching clinical trials, presentation of which may be adversely affected in cases of incomplete or incorrect diagnosis information provided. Any mention of pharmacologic agents or their on-label or off-label use should not be considered as a recommendation or endorsement for therapeutic use. Approved indications for the listed therapies may have additional criteria of medical and treatment history and combination chemotherapy. Percentage map is for visualization purposes only and is not drawn to scale. Clinical correlation is advised. Past treatment or mutation history is not being considered for selection of clinical trials presented. Clinical correlation and suitability with specific trial's inclusion and exclusion criteria are advised. Drug and clinical trial information are obtained from curated databases including NCI thesaurus and ClinicalTrials.gov. Clinical trial curated database is updated with trials verified within the last month. Tiering of clinical actionability/evidence associated with a drug recommendation may be updated in source data but not reflected as at the time of the report. For latest information, refer to the US Food and Drug Administration website and the respective source data websites for professional guidelines.

Lucence does not warrant that the data from such third-party databases, websites, or guidelines are accurate, complete, or up to date and excludes all liability for any loss or damage howsoever arising as a result of any reliance on the accuracy of the data.

Supportive Data

Test performance specifications are determined using commercial circulating tumor (ct) DNA standards, contrived samples including cell line DNA, and CSF clinical samples for specific variants at varying allele frequencies. Specificity has been determined for the entirety of bases targeted in the assay and is not variant- or hotspot-specific. The limit of detection for single nucleotide variations (SNVs)/deletions-insertions (delins) is determined to be 0.1% and 0.75% based on 25ng and 5ng input, respectively. For copy number alterations, the limit of detection has been determined to be 2-fold copy number gain/loss. The limit of detection for microsatellite instability is determined to be 5% with deletions-insertions in the microsatellite loci in the background of normal DNA.

 

 

Input DNA (ng)

Mutation class

Sensitivity by Mutant Allele Frequency

Specificity

0.1%

0.5%

0.75%

2.5%

5%

25

SNVs

>90%

>99%

 

 

>99%

>95%

Indels

>93%

>99%

 

 

>99%

>91%

5

SNVs

 

 

>99%

>99%

 

>95%

Indels

 

 

>98%

>99%

 

>91%

Clinical Reference
Recommendations for in-depth reading of a clinical nature

1. Pascual J, Attard G, Bidard FC, et al. ESMO recommendations on the use of circulating tumour DNA assays for patients with cancer: a report from the ESMO Precision Medicine Working Group. Ann Oncol. 2022;33(8):750-768. doi:10.1016/j.annonc.2022.05.520

2. Iams WT, Mackay M, Ben-Shachar R, et al. Concurrent tissue and circulating tumor DNA molecular profiling to detect guideline-based targeted mutations in a multicancer cohort. JAMA Netw Open. 2024;7(1):e2351700. Published 2024 Jan 2. doi:10.1001/jamanetworkopen.2023.51700

3. Poh J, Ngeow KC, Pek M, et al. Analytical and clinical validation of an amplicon-based next generation sequencing assay for ultrasensitive detection of circulating tumor DNA. PLoS One. 2022;17(4):e0267389. Published 2022 Apr 29. doi:10.1371/journal.pone.0267389

4. Seoane J, De Mattos-Arruda L, Le Rhun E, Bardelli A, Weller M. Cerebrospinal fluid cell-free tumour DNA as a liquid biopsy for primary brain tumours and central nervous system metastases. Ann Oncol. 2019;30(2):211-218. doi:10.1093/annonc/mdy544

Method Description
Describes how the test is performed and provides a method-specific reference

Nucleic acid (cfDNA) is extracted from the cerebrospinal fluid (CSF) sample. The extracted DNA undergoes sequencing library construction for genes targeted in the LiquidHALLMARK CSF assay. Quality and concentration of constructed libraries are determined and then sequenced on an Illumina NextSeq/NovaSeq instrument with 2x150 pair-end reads. Targeted regions listed in the LiquidHALLMARK Targets by Cancer Type (ctDNA) or a relevant subset of the list, selected to maximize detections of known hotspot mutations, are analyzed for sequence variants. Six microsatellite loci (BAT25, BAT26, NR21, NR24, NR27, MONO27) are analyzed for deletions-insertions in homopolymeric regions. Samples with microsatellite instability (MSI) detected in two or more of six sites are considered MSI-High (MSI-H) and those with MSI detected in one of six sites are considered MSI-Low (MSI-L). Sequences are aligned to reference sequences based on human genome build GRCh37/UCSC hg19. Data is analyzed using in-house bioinformatics pipelines, and proprietary sequencing error-correction methodology is applied on raw sequencing data. Copy number changes are calculated based on adjusted read count, and its variation from normalized baseline read count determined across control samples. All sequence alterations are described according to the Human Genome Variation Society (HGVS) nomenclature guidelines as published.(1) Clinical actionability of genomic findings is determined based on curated databases from publicly available data sources, including peer-reviewed publications of genomic alterations and biomarkers and associated drugs. Tiering of clinical actionability is based on Association for Molecular Pathology, American Society of Clinical Oncology, and College of American Pathologists consensus recommendation (2,3) where clinical actionability are based on Tier 1 evidence level (US Food and Drug Administration [FDA], guidelines, Phase III trials, well-powered studies with expert consensus). Drug and clinical trial information are obtained from curated databases including NCI thesaurus and ClinicalTrials.gov.

 

1. den Dunnen JT, Dalgleish R, Maglott DR, et al. HGVS Recommendations for the Description of Sequence Variants: 2016 Update. Hum Mutat. 2016;37(6):564-569. doi:10.1002/humu.22981

2. Li MM, Datto M, Duncavage EJ, et al. Standards and Guidelines for the Interpretation and Reporting of Sequence Variants in Cancer: A Joint Consensus Recommendation of the Association for Molecular Pathology, American Society of Clinical Oncology, and College of American Pathologists. J Mol Diagn. 2017;19(1):4-23. doi:10.1016/j.jmoldx.2016.10.002

3. Wagner AH, Walsh B, Mayfield G, et al. A harmonized meta-knowledgebase of clinical interpretations of somatic genomic variants in cancer. Nat Genet. 2020;52(4):448-457. doi:10.1038/s41588-020-0603-8

PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information

Referral

Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Monday through Friday

Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

8 to 12 days

Performing Laboratory Location
Indicates the location of the laboratory that performs the test

Lucence Health, Inc.
CLIA Number: 05D2200843

Fees
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.

  • Authorized users can sign in to Test Prices for detailed fee information.
  • Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
  • Prospective clients should contact their account representative. For assistance, contact Customer Service.

Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.

This clinical test was developed and its performance characteristics determined by Lucence Health Inc. It has not been cleared or approved by the US Food and Drug Administration (FDA). The FDA does not require this test to go through premarket FDA review. This test is used for clinical purposes and should not be regarded as investigational or for research, unless otherwise stated in the report. Lucence Health Inc. is a Clinical Laboratory Improvement Amendments (CLIA)-certified clinical diagnostic laboratory (CLIA ID Number: 05D2200843) and is accredited to College of American Pathologists (CAP) laboratory quality standards.

CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

CPT codes are provided by the performing laboratory.

81455

LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.

Test Id Test Order Name Order LOINC Value
LUCSF LiquidHALLMARK CSF Not Provided
Result Id Test Result Name Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
LU003 LiquidHALLMARK CSF Not Provided

Test Setup Resources

Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.

Excel | Pdf

Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.

Normal Reports | Abnormal Reports

SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.

SI Normal Reports | SI Abnormal Reports

Test Update Resources

Change Type Effective Date
New Test 2026-06-18