TEST CATALOG ORDERING & RESULTS SPECIMEN HANDLING CUSTOMER SERVICE EDUCATION & INSIGHTS
Test Catalog

Test ID: CLAV    
Cortisol, Left Adrenal Vein, Serum

Specimen Type Describes the specimen type validated for testing

Serum

Specimen Required Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Container/Tube: Red top

Specimen Volume: 1.5 mL

Collection Instructions: Morning (8 a.m.) and afternoon (4 p.m.) specimens are preferred.

Additional Information:

1. Include time of draw.

2. If multiple specimens are drawn, send separate order for each specimen.

Specimen Minimum Volume Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

0.5 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
 

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen TypeTemperatureTimeSpecial Container
SerumRefrigerated (preferred)28 days
 Ambient 28 days
 Frozen 28 days