TEST CATALOG ORDERING & RESULTS SPECIMEN HANDLING CUSTOMER SERVICE EDUCATION & INSIGHTS
Test Catalog

Test ID: OXYMU    
Oxymorphone Confirmation, Random, Urine

Specimen Type Describes the specimen type validated for testing

Urine

Specimen Required Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Collection Container/Tube: Plastic urine container

Submission Container/Tube: Plastic, 60-mL urine bottle

Specimen Volume: 20 mL

Collection Instructions:

1. Collect a random urine specimen.

2. Submit 20 mL in 1 plastic bottle.

3. No preservative.

Additional Information:

1. No specimen substitutions.

2. No STATS are accepted for this procedure.

3. For situations where chain of custody is required, a Chain-of-Custody Kit (T282) is available. For chain-of-custody testing, order OXYCX / Oxycodone with Metabolite Confirmation, Chain of Custody, Urine

4. Additional drug panels and specific requests are available. Call 800-533-1710 or 507-266-5700.

5. If urine creatinine is required or adulteration of the sample is suspected, the following test should be requested, ADULT / Adulterants Survey, Urine. For additional information, please refer to ADULT / Adulterants Survey, Urine.

Forms

If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.

Specimen Minimum Volume Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

2.5 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Gross hemolysis OK
Gross icterus OK

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen TypeTemperatureTimeSpecial Container
UrineRefrigerated (preferred)28 days
 Frozen 28 days
 Ambient 14 days