TEST CATALOG ORDERING & RESULTS SPECIMEN HANDLING CUSTOMER SERVICE EDUCATION & INSIGHTS
Test Catalog

Test ID: DENGC    
Dengue Virus, Molecular Detection, PCR, Spinal Fluid

Testing Algorithm Delineates situations when tests are added to the initial order. This includes reflex and additional tests.

See Mosquito-borne Disease Laboratory Testing in Special Instructions.

Specimen Type Describes the specimen type validated for testing

CSF

Advisory Information

The presence of dengue virus nucleic acid in cerebrospinal fluid (CSF) or serum (as detected by molecular assays [This test or DENGS / Dengue Virus, Molecular Detection, PCR, Serum] overlaps with the presence of dengue virus nonstructural protein 1 (NS1) antigen (DNSAG / Dengue Virus NS1 Antigen, Serum). Patients with a history of symptoms for more than 1 week may be negative by molecular tests (ie, real-time PCR) and may require serologic testing (DENVP / Dengue Virus Antibody/Antigen Panel, Serum) to confirm the diagnosis of dengue virus infection.

Specimen Required Defines the optimal specimen required to perform the test and the preferred volume to complete testing

Supplies: Aliquot Tube, 5 mL (T465)

Preferred: 12 x 75-mm screw cap vial

Acceptable: Sterile screw cap vial

Container/Tube: Sterile vial

Specimen Volume: 0.5 mL

Collection Instructions: Do not centrifuge.

Special Instructions Library of PDFs including pertinent information and forms related to the test

Specimen Minimum Volume Defines the amount of sample necessary to provide a clinically relevant result as determined by the Testing Laboratory

0.3 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Heat-inactivated specimen Reject

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included

Specimen TypeTemperatureTimeSpecial Container
CSFRefrigerated (preferred)7 days
 Frozen 7 days