Test Id : FVZGC
Varicella-Zoster Virus Antibody, IgG, CSF
Method Name
A short description of the method used to perform the test
Semi-Quantitative Chemiluminescent Immunoassay
NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test
Aliases
Lists additional common names for a test, as an aid in searching
CSF VZV
Herpes Zoster Antibodies CSF
Varicella-Zoster Antibody CSF
Varicella-zoster IgG CSF
VZ AB IgG CSF
VZ Ab, CSF
VZECSF
Specimen Type
Describes the specimen type validated for testing
CSF
Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing
Specimen Type: Spinal fluid (CSF)
Container/Tube: Sterile plastic container
Specimen Volume: 0.5 mL
Collection Instructions:
1. Collect 0.5 mL CSF in sterile plastic container.
2. Ship refrigerated.
Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
0.3 mL
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
Hemolysis | Reject |
Specimens other than CSF Contaminated or heat-inactivated specimens Xanthochromic specimens (yellow color) | Reject |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
CSF | Refrigerated (preferred) | 14 days | |
Frozen | 365 days |
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
0.99 S/CO or less: Negative - No significant level of detectable varicella-zoster IgG antibody.
1.00 S/CO or greater: Positive - IgG antibody to varicella-zoster detected, which may indicate a current or past varicella-zoster infection.
Interpretation
Provides information to assist in interpretation of the test results
The detection of antibodies to varicella-zoster in cerebrospinal fluid may indicate central nervous system infection. However, consideration must be given to possible contamination by blood or transfer of serum antibodies across the blood-brain barrier.
PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information
Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
Sunday through Saturday
Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
Performing Laboratory Location
Indicates the location of the laboratory that performs the test
Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
- Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
CPT codes are provided by the performing laboratory.
86787
LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
FVZGC | VZV Antibody IgG CSF | 104459-3 |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
Z4272 | VZV Antibody IgG CSF | 104459-3 |
Test Setup Resources
Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.
Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.
SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.
Test Update Resources
Change Type | Effective Date |
---|---|
Test Changes - Reference Value | 2025-04-21 |
Test Changes - Reference Value | 2024-10-07 |