TEST CATALOG ORDERING & RESULTS SPECIMEN HANDLING CUSTOMER SERVICE EDUCATION & INSIGHTS
Test Catalog

Test ID: MNU    
Manganese, 24 Hour, Urine

Method Description Describes how the test is performed and provides a method-specific reference

This assay is performed on an inductively coupled plasma-mass spectrometer in dynamic reaction cell mode. Calibrating standards and blanks are diluted with an aqueous acidic diluent containing internal standards. Quality control specimens and patient samples are diluted in an identical manner. In turn, all diluted blanks, calibrating standards, quality control specimens, and patient specimens are aspirated into a pneumatic nebulizer and the resulting aerosol directed to the hot plasma discharge by a flow of argon. In the annular plasma the aerosol is vaporized, atomized, then ionized. The ionized gases plus neutral species formed in the annular plasma space are aspirated from the plasma through an orifice into a quadrupole mass spectrometer. The mass range from 1 to 263 amu is rapidly scanned multiple times and ion counts tabulated for each mass of interest. Instrument response is defined by the linear relationship of analyte concentration vs. ion count ratio (analyte ion count/internal standard ion count). Analyte concentrations are derived by reading the ion count ratio for each mass of interest and determining the concentration from the response line.(Unpublished Mayo method)

PDF Report Indicates whether the report includes an additional document with charts, images or other enriched information

No

Day(s) Performed Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.

Tuesday

Report Available The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.

1 to 5 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location Indicates the location of the laboratory that performs the test

Rochester