Test Id : FMMPP
MyoMarker 3 Plus Profile
Method Name
A short description of the method used to perform the test
Enzyme-linked immunosorbent assay (ELISA); RIPA Gel Radiography
NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test
Aliases
Lists additional common names for a test, as an aid in searching
FMMPP
Myositis Panel 3 Plus
Myomarker 3 plus
Myo Marker 3 Plus
Myo 3 Plus
Myositis
Specimen Type
Describes the specimen type validated for testing
Serum
Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing
Collection Container/Tube: 10 mL Red
Submission Container/Tube: Plastic vial
Specimen Volume: 5 mL
Acceptable: SST
Collection Instructions:
Specimen Minimum Volume
Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
4 mL (volume does NOT allow for repeat testing)
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
Gross hemolysis: | Reject |
Thawing: | Warm OK; Cold OK |
Gross lipemia: | Reject |
Gross icterus | Reject |
Other: | Anything other than serum; bacterial contamination |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Ambient | 7 days | ||
Frozen | 60 days |
Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
The MyoMarker Panel 3 Plus can be used to assist in the diagnosis of dermatomyositis, polymyositis and the anti-synthetase syndrome. Furthermore, it allows characterization of various subsets of these disorders and offers prognostic information.
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
Anti-PL-7 Ab, Anti-PL-12 Ab, Anti-EJ Ab, Anti-OJ Ab, Anti-SRP Ab, Anti-Mi-2-Ab, Anti-U3 RNP (Fibrillarin), Anti-U2 RNP Ab, Anti-Ku Ab:
Reference Range: Negative
Interpretation for:
Anti-Jo-1 Ab, Anti-TIF-1gamma Ab, Anti-MDA-5-Ab (CADM-140), Anti-NXP-2 (P140) Ab, Anti-SAE1 Ab IgG, Anti-PM/Scl-100 Ab, Anti-SS-A 52kD Ab IgG, Anti-U1-RNP Ab:
Reference Range: <20
Negative: <20 units
Weak Positive: 20-39 units
Moderate Positive: 40-80 units
Strong Positive:>80 units
PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information
Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
Batched weekly
Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
Performing Laboratory Location
Indicates the location of the laboratory that performs the test
Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
- Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
CPT codes are provided by the performing laboratory.
83516 x 10
86235 x 7
LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
FMMPP | MyoMarker 3 Plus Profile | Not Provided |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
Z5693 | Anti-Jo-1 Ab | 35333-4 |
Z5694 | Anti-PL-7 Ab | 33772-5 |
Z5695 | Anti-PL-12 Ab | 33771-7 |
Z5696 | Anti-EJ Ab | 45149-2 |
Z5697 | Anti-OJ Ab | 45152-6 |
Z5698 | Anti-SRP Ab | 33921-8 |
Z5699 | Anti-Mi-2-Ab | 18485-3 |
Z5700 | Anti-U3 RNP (Fibrillarin) | 49963-2 |
Z5701 | Anti-MDA-5 Ab (CADM-140) | 88725-7 |
Z5702 | Anti-NXP-2 (P140) Ab | 82425-0 |
Z5703 | Anti-TIF-1gamma Ab | 88739-8 |
Z5704 | Anti-PM/Scl-100 Ab | 31562-2 |
Z5705 | Anti-U2 RNP Ab | 68549-5 |
Z5706 | Anti-U1 RNP Ab | 57662-9 |
Z5707 | Anti-Ku Ab | 18484-6 |
Z5708 | Anti-SS-A 52kD Ab, IgG | 70257-1 |
Z5709 | Anti-SAE1 Ab, IgG | 101220-2 |
Test Setup Resources
Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.
Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.
SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.
Test Update Resources
Change Type | Effective Date |
---|---|
Test Status - Test Resumed | 2025-04-29 |
Test Status - Test Resumed | 2025-04-09 |
Test Changes - Referral Fee | 2025-03-20 |
Test Status - Test Delay | 2025-02-24 |
Test Status - Test Delay | 2024-12-27 |