Test Id : NECT4
Nectin-4, Semi-Quantitative Immunohistochemistry, Manual
Useful For
Suggests clinical disorders or settings where the test may be helpful
Identifying nectin-4 overexpression in bladder cancer and other cancers
Method Name
A short description of the method used to perform the test
Immunohistochemistry (IHC)
NY State Available
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Reporting Name
Lists a shorter or abbreviated version of the Published Name for a test
Aliases
Lists additional common names for a test, as an aid in searching
PVRL4
Poliovirus receptor like 4
Specimen Type
Describes the specimen type validated for testing
Special
Shipping Instructions
Attach the green "Attention Pathology" address label (T498) to the outside of the transport container before putting into the courier mailer.
Necessary Information
A pathology/diagnostic report and a brief history are required.
Specimen Required
Defines the optimal specimen required to perform the test and the preferred volume to complete testing
Specimen Type: Tissue
Supplies: Pathology Packaging Kit (T554)
Collection Instructions: Formalin-fixed, paraffin-embedded tissue block; or 3 unstained glass, positively-charged slides with 4-microns formalin-fixed, paraffin-embedded tissue
Additional Information: One slide will be stained with hematoxylin and eosin and returned.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
Wet/frozen tissue Decalcified paraffin embedded tissue Cytology smears Non-formalin fixed tissue Nonparaffin embedded tissue Noncharged slides ProbeOn slides Snowcoat slides | Reject |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Special | Ambient (preferred) | ||
Refrigerated |
Useful For
Suggests clinical disorders or settings where the test may be helpful
Identifying nectin-4 overexpression in bladder cancer and other cancers
Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
Nectin-4, also known as poliovirus receptor-like 4 (PVRL4), is overexpressed in many cancers, in particular bladder cancer. An antibody drug conjugate, enfortumab vedotin, targets the cell surface protein nectin-4. Some studies suggest that tumors with high expression of nectin-4 are more likely responsive to drug therapy.
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
An interpretive report will be provided.
Interpretation
Provides information to assist in interpretation of the test results
This test does not include pathologist interpretation, only technical performance of the stain. If interpretation is required, order PATHC / Pathology Consultation for a full diagnostic evaluation or second opinion of the case.
The positive and negative controls are verified as showing appropriate immunoreactivity.
Interpretation of this test should be performed in the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances
This test has been validated for nondecalcified paraffin-embedded tissue specimens fixed in 10% neutral buffered formalin. Recommended fixation time is between 6 and 48 hours. This test has not been validated on tissues subjected to the decalcification process or use of alternative fixatives.
Age of a cut paraffin section can affect immunoreactivity. Stability thresholds vary widely among published literature and are antigen dependent. Best practice is for paraffin sections to be cut within 6 weeks.
Clinical Reference
Recommendations for in-depth reading of a clinical nature
1. Heath EI, Rosenberg JE. The biology and rationale of targeting nectin-4 in urothelial carcinoma. Nat Rev Urol. 2021;18(2):93-103
2. Bouleftour W, Guillot A, Magne N. The anti-nectin 4: A promising tumor cells target. A systematic review. Mol Cancer Ther. 2022;21(4):493-501
3. Takano A, Ishikawa N, Nishino R, et al. Identification of nectin-4 oncoprotein as a diagnostic and therapeutic target for lung cancer. Cancer Res. 2009;69(16):6694-6703
Method Description
Describes how the test is performed and provides a method-specific reference
Immunohistochemistry on sections of paraffin-embedded tissue.(Unpublished Mayo method)
PDF Report
Indicates whether the report includes an additional document with charts, images or other enriched information
Day(s) Performed
Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
Monday through Friday
Report Available
The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
Performing Laboratory Location
Indicates the location of the laboratory that performs the test
Fees :
Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
- Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
CPT codes are provided by the performing laboratory.
88360
LOINC® Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
Test Id | Test Order Name | Order LOINC Value |
---|---|---|
NECT4 | Nectin-4, SemiQuant IHC, Manual | In Process |
Result Id | Test Result Name |
Result LOINC Value
Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
|
---|---|---|
622261 | Interpretation | 59465-5 |
622262 | Participated in the Interpretation | No LOINC Needed |
622263 | Report electronically signed by | 19139-5 |
622264 | Material Received | 81178-6 |
622265 | Disclaimer | 62364-5 |
622266 | Case Number | 80398-1 |
Test Setup Resources
Setup Files
Test setup information contains test file definition details to support order and result interfacing between Mayo Clinic Laboratories and your Laboratory Information System.
Sample Reports
Normal and Abnormal sample reports are provided as references for report appearance.
SI Sample Reports
International System (SI) of Unit reports are provided for a limited number of tests. These reports are intended for international account use and are only available through MayoLINK accounts that have been defined to receive them.
Test Update Resources
Change Type | Effective Date |
---|---|
New Test | 2025-07-31 |