Test Id : HBPES
Hepatitis B Virus Past Exposure Panel, Serum
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Screening for past exposure to hepatitis B virus (HBV)
 
Determining HBV infection and immunity status prior to initiating chemotherapy or other immunosuppressive agents
    
        Highlights
    
    This test panel is intended to screen for presence of past or active hepatitis B viral infection in individuals who will be receiving chemotherapy, immunosuppressive therapy, or organ transplantation.
    
        Profile Information
            
                
                
                    
                    A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.
                
            
    
    | Test Id | Reporting Name | Available Separately | Always Performed | 
|---|---|---|---|
| HBGSN | HBs Antigen Scrn, S | Yes | Yes | 
| HBCSN | HBc Total Ab Scrn, S | Yes | Yes | 
| HBBSN | HBs Antibody Scrn, S | Yes | Yes | 
    
        Reflex Tests
            
                
                
                    
                    Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.
                
            
    
    | Test Id | Reporting Name | Available Separately | Always Performed | 
|---|---|---|---|
| HBGSC | HBs Antigen Screen Confirmation, S | No | No | 
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    If hepatitis B surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.
For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Method Name
            
                
                
                    
                    A short description of the method used to perform the test
                
            
    
    Electrochemiluminescence Immunoassay (ECLIA)
    
        NY State Available
            
                
                
                    
                    Indicates the status of NY State approval and if the test is orderable for NY State clients.
                
            
    
    
    
        Reporting Name
            
                
                
                    
                    Lists a shorter or abbreviated version of the Published Name for a test
                
            
    
    
    
        Aliases
            
                
                
                    
                    Lists additional common names for a test, as an aid in searching
                
            
    
    Chronic Hepatitis B
HBV
HBVPE
HBPESx
Hepatitis B
Hepatitis B Screen
Hepatitis Profile
Past Exposure Hep B
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    If hepatitis B surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.
For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Specimen Type
            
                
                
                    
                    Describes the specimen type validated for testing
                
            
    
        Serum SST
    
        Necessary Information
    
    Date of collection is required.
    
        Specimen Required
            
                
                
                    
                    Defines the optimal specimen required to perform the test and the preferred volume to complete testing
                
            
    
    Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Serum gel (red-top tubes are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1.2 mL
Collection Instructions:
1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot serum into plastic vial.
    
        Special Instructions
            
                
                
                    
                    Library of PDFs including pertinent information and forms related to the test
                
            
    
    
    
        Specimen Minimum Volume
            
                
                
                    
                    Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
                
            
    
    0.9 mL
    
        Reject Due To
            
                
                
                    
                    Identifies specimen types and conditions that may cause the specimen to be rejected
                
            
    
    | Gross hemolysis | Reject | 
| Gross lipemia | Reject | 
| Gross icterus | Reject | 
    
        Specimen Stability Information
            
                
                
                    
                    Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
                
            
    
    | Specimen Type | Temperature | Time | Special Container | 
|---|---|---|---|
| Serum SST | Frozen (preferred) | 90 days | |
| Ambient | 72 hours | ||
| Refrigerated | 6 days | 
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Screening for past exposure to hepatitis B virus (HBV)
 
Determining HBV infection and immunity status prior to initiating chemotherapy or other immunosuppressive agents
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    If hepatitis B surface antigen (HBsAg) is reactive, then HBsAg confirmation will be performed at an additional charge.
For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Clinical Information
            
                
                
                    
                    Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
                
            
    
    Hepatitis B virus (HBV) is a DNA virus that is endemic throughout the world. HBV is transmitted parenterally or percutaneously from exposure to contaminated blood, blood products, or injection needles, sexually from exposure to body fluids from infected individuals, or perinatally from mother to child during birth delivery by contact with infected mother's blood and vaginal secretions. Transplacental transmission from mother to fetus is uncommon.
 
Hepatitis B virus persists and causes chronic infection (defined as being positive for hepatitis B virus surface antigen [HBsAg] in serum or plasma for minimum 6 months) in about 10% of individuals who had acute infection during childhood. These individuals may become asymptomatic HBV carriers (ie, inactive chronic hepatitis B), while others may develop chronic liver diseases including cirrhosis and hepatocellular carcinoma. Asymptomatic HBV carriers are at risk (up to 50%) for decompensation of liver function with acute HBV replication (ie, HBV reactivation) during immunosuppression from chemotherapy, immunosuppressive therapy, or organ transplantation.
 
Individuals who recovered from acute hepatitis B (defined as being negative for HBsAg, positive for HBc total antibodies, negative or positive for HBs antibody) are at lower risk (up to 20%) of HBV reactivation than those with inactive chronic hepatitis B during immunosuppressive therapy or organ transplantation.
 
For individuals born in regions of the world where HBV prevalence is moderate to high, universal HBV serologic screening before initiation of immunosuppressive therapy is recommended. In the absence of systematic, risk-based testing, universal HBV serologic screening is an option to reduce the risk of missing individuals with HBV infection prior to initiation of immunosuppressive treatment.
    
        Reference Values
            
                
                
                    
                    Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
                
            
    
    Negative
    
        Interpretation
            
                
                
                    
                    Provides information to assist in interpretation of the test results
                
            
    
    Hepatitis B virus surface antigen (HBsAg) is the first serologic marker appearing in blood 6 to 8 weeks after exposure to hepatitis B virus (HBV). A confirmed positive HBsAg result is indicative of acute or chronic hepatitis B. In acute cases, HBsAg usually disappears 1 to 2 months after the onset of symptoms. Persistence of HBsAg for more than a 6-month duration indicates development of either a chronic carrier state or chronic hepatitis B.
 
Hepatitis B virus surface antibody (anti-HBs) appears with the resolution of HBV infection and disappearance of HBsAg. A positive result indicates recovery from acute or chronic hepatitis B or acquired immunity from HBV vaccination. This assay does not differentiate between a vaccine-induced immune response and recovery from HBV infection. Per assay manufacturer's instructions for use, positive results are defined as anti-HBs levels of 10.0 mIU/mL or greater, with adequate immunity to hepatitis B after recovery from past infection or HBV vaccination. This anti-HBs level to achieve immunity is in accordance with current Centers for Disease Control and Prevention guidance.  Individuals with anti-HBs levels of 10 mIU/mL or greater after completing an HBV vaccination series are considered protected from hepatitis B infection.
 
Negative anti-HBs results, defined as anti-HBs levels of less than 10.0 mIU/mL, indicate a lack of recovery from acute or chronic hepatitis B or inadequate immune response to HBV vaccination.
 
Hepatitis B virus core (HBc) total and IgM antibodies appear shortly after the onset of symptoms of HBV infection and may be the only serologic marker remaining years after exposure to HBV. A positive result indicates exposure to HBV infection. A positive anti-HBs result along with a positive HBc total antibody result is indicative of recovery from HBV infection. A positive anti-HBs result with a negative HBc total antibody result is consistent with immunity to hepatitis B from HBV vaccination.
 
Table. Summary of interpretation of the various HBV serologic test result profiles 
| HBV serologic test   results | Interpretation | ||
| HBsAg | HBc total Ab | HBsAb | |
| + | + | - | Chronic hepatitis B | 
| - | + | + | Past HBV infection | 
| - | + | - | Past HBV infection or possible false-positive test result | 
| - | - | + | Immunity from HBV vaccination | 
| - | - | - | No previous exposure to hepatitis B virus (not immune) | 
    
        Cautions
            
                
                
                    
                    Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances
                
            
    
    Assay performance characteristics have not been established for the following specimen characteristics:
-Grossly icteric (total bilirubin level of >25 mg/dL)
-Grossly lipemic (intralipid level of >1000 mg/dL)
-Grossly hemolyzed (hemoglobin level of >500 mg/dL)
-Contain particulate matter
-Cadaveric specimens
-Heat inactivated specimens
    
        Clinical Reference
            
                
                
                    
                    Recommendations for in-depth reading of a clinical nature
                
            
    
    1. LeFevre ML, et al. Screening for hepatitis B virus infection in nonpregnant adolescents and adults: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med. 2014;161(1):58-66. doi:10.7326/M14-10182
2. Terrault NA, Lok ASF, McMahon BJ, et al. Update on prevention, diagnosis, and treatment of chronic hepatitis B: AASLD 2018 hepatitis B guidance. Hepatology. 2018; 67(4):1560-1599. doi:10.1002/hep.29800 
3. Centers for Disease Control and Prevention: Prevention of hepatitis B virus infection in the United States: Recommendations of the Advisory Committee on Immunization Practices. MMWR Recomm Rep. 2018; 67(1):1-31. Accessed July 17, 2025. Available at www.cdc.gov/mmwr/volumes/67/rr/pdfs/rr6701-H.PDF
4. Centers for Disease Control and Prevention (CDC), Division of Viral Hepatitis: Clinical Testing and Diagnosis for Hepatitis B. CDC; Updated January 31, 2025. Accessed July 17, 2025. Available at www.cdc.gov/hepatitis-b/hcp/diagnosis-testing/ 
5. Conners EE, Panagiotakopoulos L, Hofmeister MG, et al. Screening and testing for hepatitis B virus infection: CDC Recommendations - United States, 2023. MMWR Recomm Rep. 2023;72(1):1-25. Published 2023 Mar 10. doi:10.15585/mmwr.rr7201a1
    
        Method Description
            
                
                
                    
                    Describes how the test is performed and provides a method-specific reference
                
            
    
    Hepatitis B Surface Antigen Screen:
The Elecsys HBsAg (hepatitis B surface antigen) II assay is performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HBsAg present in the patient's sample reacts with two biotinylated monoclonal hepatitis B surface antibody (anti-HBs) and a mixture of monoclonal anti-HBs and polyclonal anti-HBsAg antibodies labeled with a ruthenium complex react to form a sandwich complex. After addition of streptavidin-coated microparticles, the complexes become bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Test results for each patient's sample are determined by comparing the electrochemiluminescence signal generated from the reaction product to the cutoff index (COI) value set from reagent lot-specific assay calibrations.(Package insert: Elecsys HBsAG II. Roche Diagnostics; v3.0, 02/2022)
 
Hepatitis B Surface Antigen Confirmation:
The Elecsys HBsAg II Auto Confirm assay is performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. This test is based on 2 parallel measurements. For the first measurement, the sample is treated with the control pretreatment reagent (PT2) prior to immunoreaction. This measurement serves as a reference. For the second measurement the sample is treated with the confirmatory pretreatment reagent (PT1) prior to immunoreaction. During incubation with confirmatory pretreatment, unlabeled polyclonal anti-HBsAg antibodies are bound to the sample HBsAg and thereby block the binding sites for the labeled antibodies used in the following immunoreaction. The confirmation result (%) is automatically assessed by determining the ratio of both measurements.
 
During testing, the auto-diluted sample is incubated with control pretreatment and confirmatory pretreatment, followed by formation of sandwich complexes of biotinylated monoclonal anti-HBsAg antibodies and a mixture of monoclonal anti-HBsAg antibody and polyclonal anti-HBsAg antibodies labeled with a ruthenium complex. After addition of streptavidin-coated microparticles, the complexes become bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are then washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Results are determined by comparing the electrochemiluminescence signal generated from the reaction product to the cutoff index value set from reagent lot-specific assay calibration. The confirmation result (%) is calculated from the ratio of the COI obtained for the measurement with confirmatory pretreatment to the COI obtained for the measurement with control pretreatment.(Package insert: Elecsys HBsAg II Auto Confirm. Roche Diagnostics; v1.0, 12/2020)
 
Hepatitis B Surface Antibody:
The Elecsys Anti-HBs (hepatitis B surface) quantitative assay is performed using an electrochemiluminescent immunoassay on the automated cobas e 801 immunochemistry analyzer. Anti-HBs present in patient's serum sample reacts with the biotinylated HBsAg (ad and ay subtypes) and HBsAg (ad/ay) labeled with a ruthenium complex to form a sandwich complex. After addition of streptavidin-coated microparticles, the complexes bind to a solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. The emission signal generated is directly proportional to the concentration of anti-HBs present in the patient's serum sample.(Package insert: Elecsys Anti-HBs II. Roche Diagnostics; v1.0, 09/2024)
 
Hepatitis B Core Total Antibodies:
The Elecsys Anti-HBc (hepatitis B core) II assay is performed using an electrochemiluminescence immunoassay on the automated cobas e 801 analyzer. Anti-HBc present in the patient's sample is pretreated first with a reducing reagent, and after the addition of hepatitis B virus core antigen (HBcAg), complexes are formed with anti-HBc in the sample. The remaining unbound sites on the HBcAg become occupied after addition of biotinylated antibodies and ruthenium complex-labeled antibodies specific for HBcAg, together with streptavidin-coated microparticles. The entire complex becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. After unbound substances are washed away, voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Results are determined by comparing the electrochemiluminescence signal generated from the reaction product of the sample to the COI value set from assay reagent lot-specific assay calibration.(Package insert: Elecsys Anti-HBc II. Roche Diagnostics; v1.0, 04/2022)
    
        PDF Report
            
                
                
                    
                    Indicates whether the report includes an additional document with charts, images or other enriched information
                
            
    
    
    
        Day(s) Performed
            
                
                
                    
                    Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
                
            
    
    Monday through Friday, Sunday
    
        Report Available
            
                
                
                    
                    The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
                
            
    
    
    
        Specimen Retention Time
            
                
                
                    
                    Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
                
            
    
    
    
        Performing Laboratory Location
            
                
                
                    
                    Indicates the location of the laboratory that performs the test
                
            
    
    
    
        Fees :
            
                
                
                    
                    Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
                
            
    
    - Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
    
        Test Classification
            
                
                
                    
                    Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
                
            
    
    This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.
    
        CPT Code Information
            
                
                
                    
                    Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
                
            
    
    CPT codes are provided by the performing laboratory.
86706
86704
87340
87341 (if appropriate)
G0499 (if appropriate)
    
        LOINC® Information
            
                
                
                    
                    Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
                
            
    
    | Test Id | Test Order Name | Order LOINC Value | 
|---|---|---|
| HBPES | Hepatitis B Past Exposure, S | 77190-7 | 
| Result Id | Test Result Name | Result LOINC Value 
                                        
                                        Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
                                     | 
|---|---|---|
| HBCSN | HBc Total Ab Scrn, S | 13952-7 | 
| HBAGS | HBs Antigen Scrn, S | 5196-1 | 
| HBSQN | HBs Antibody, Quantitative, S | 5193-8 | 
| HBASN | HBs Antibody Scrn, S | 10900-9 |