Test Id : HEAB
Hepatitis B Virus e Antibody, Serum
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Determining the presence or absence of detectable hepatitis B virus e antibody in monitoring infection status of individuals with chronic hepatitis B
 
Determining infectivity of hepatitis B virus (HBV) carriers
 
Monitoring serologic response of chronically HBV-infected patients receiving antiviral therapy
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Method Name
            
                
                
                    
                    A short description of the method used to perform the test
                
            
    
    Electrochemiluminescence Immunoassay (ECLIA)
    
        NY State Available
            
                
                
                    
                    Indicates the status of NY State approval and if the test is orderable for NY State clients.
                
            
    
    
    
        Reporting Name
            
                
                
                    
                    Lists a shorter or abbreviated version of the Published Name for a test
                
            
    
    
    
        Aliases
            
                
                
                    
                    Lists additional common names for a test, as an aid in searching
                
            
    
    Antibody to Hepatitis Be antigen
Hepatitis Be antibody
Anti-HBe
HBe Ab
Hepatitis Be Ab
HEAB
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Specimen Type
            
                
                
                    
                    Describes the specimen type validated for testing
                
            
    
        Serum SST
    
        Additional Testing Requirements
    
    If ordered with HBVQN / Hepatitis B Virus (HBV) DNA Detection and Quantification by Real-Time PCR, Serum; send separate vials.
    
        Necessary Information
    
    Date of collection is required.
    
        Specimen Required
            
                
                
                    
                    Defines the optimal specimen required to perform the test and the preferred volume to complete testing
                
            
    
    Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Serum gel (red-top tubes are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 0.7 mL
Collection Instructions:
1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot serum into plastic vial.
    
        Special Instructions
            
                
                
                    
                    Library of PDFs including pertinent information and forms related to the test
                
            
    
    
    
        Forms
    
    If not ordering electronically, complete, print, and send 1 of the following with the specimen:
    
        Specimen Minimum Volume
            
                
                
                    
                    Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
                
            
    
    0.5 mL
    
        Reject Due To
            
                
                
                    
                    Identifies specimen types and conditions that may cause the specimen to be rejected
                
            
    
    | Gross hemolysis | Reject | 
| Gross lipemia | Reject | 
| Gross icterus | Reject | 
    
        Specimen Stability Information
            
                
                
                    
                    Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
                
            
    
    | Specimen Type | Temperature | Time | Special Container | 
|---|---|---|---|
| Serum SST | Frozen (preferred) | 90 days | |
| Ambient | 72 hours | ||
| Refrigerated | 6 days | 
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Determining the presence or absence of detectable hepatitis B virus e antibody in monitoring infection status of individuals with chronic hepatitis B
 
Determining infectivity of hepatitis B virus (HBV) carriers
 
Monitoring serologic response of chronically HBV-infected patients receiving antiviral therapy
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    For more information see Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Clinical Information
            
                
                
                    
                    Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
                
            
    
    During recovery from acute hepatitis B, the hepatitis B e virus antigen (HBeAg) level declines and becomes undetectable and HBe antibody (anti-HBe) appears in the serum. Anti-HBe usually remains detectable for many years after recovery from acute hepatitis B.
 
In hepatitis B virus (HBV) carriers and in patients with chronic hepatitis B, positive anti-HBe results usually indicate inactivity of the virus and low infectivity of the patients. Positive anti-HBe results in the presence of detectable HBV DNA in serum indicate active viral replication.
 
For more information, see the following:
-Hepatitis B: Testing Algorithm for Screening, Diagnosis, and Management
    
        Reference Values
            
                
                
                    
                    Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
                
            
    
    
            
    
        Interpretation
            
                
                
                    
                    Provides information to assist in interpretation of the test results
                
            
    
    Absence of hepatitis B e antigen (HBeAg) with appearance of HBe antibody (anti-HBe) is consistent with inactivity of the virus and loss of hepatitis B virus (HBV) infectivity.
 
Although resolution of chronic HBV infection generally follows the appearance of anti-HBe, the HBV carrier state may persist.
    
        Cautions
            
                
                
                    
                    Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances
                
            
    
    For diagnostic purposes, results should always be assessed in conjunction with the patient’s medical history, clinical examination, and other findings.
Serum specimens from individuals taking multivitamins containing biotin or biotin supplements at 20 mg or more per day may have false-positive hepatitis B e antibody (anti-HBe) test results due to interference of biotin with the assay. Such individuals should stop taking these biotin-containing dietary supplements for a minimum of 12 hours before blood collection for this test.
In rare cases, interference due to extremely high titers of antibodies to analyte-specific antibodies, streptavidin, or ruthenium can occur, causing false-positive anti-HBe results. These effects are minimized by suitable test design.
Appearance of anti-HBe in serum does not completely rule-out chronic hepatitis B virus carrier state or infectivity.
Assay performance characteristics have not been established when Elecsys Anti-HBe assay is used in conjunction with other manufacturers’ assays for specific HBV serological markers.
Assay performance characteristics have not been established for the following specimen characteristics or specimen types:
-Grossly icteric (total bilirubin level of >66 mg/dL)
-Grossly lipemic (intralipid level of >2000 mg/dL)
-Grossly hemolyzed (hemoglobin level of >2000 mg/dL)
-Specimen types other than serum
    
        Clinical Reference
            
                
                
                    
                    Recommendations for in-depth reading of a clinical nature
                
            
    
    1. LeFevre ML, U.S. Preventive Services Task Force: Screening for hepatitis B virus infection in nonpregnant adolescents and adults: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med. 2014; 161(1):58-66. doi:10.7326/M14-1018
2. Terrault NA, Bzowej NH, Chang KM, et al. AASLD guidelines for treatment of chronic hepatitis B. Hepatology. 2016; 63(1):261-283
3. WHO guidelines on hepatitis B and C testing. Geneva: World Health Organization; February 2017. Accessed December21, 2023. Available at www.who.int/publications/i/item/9789241549981
4. Jackson K, Locarnini S, Gish R. Diagnostics of hepatitis B virus: Standard of care and investigational. Clin Liver Dis. 2018; 12(1):5-11. doi:10.1002/cld.729
5. Coffin CS, Zhou K, Terrault NA. New and old biomarkers for diagnosis and management of chronic hepatitis B virus infection. Gastroenterology. 2019; 156(2):355-368. doi:10.1053/j.gastro.2018.11.037
6. Conners EE, Panagiotakopoulos L, Hofmeister MG, et al. Screening and testing for hepatitis B virus infection: CDC Recommendations-United States, 2023. MMWR Recomm Rep. 2023;72(1):1-25
    
        Method Description
            
                
                
                    
                    Describes how the test is performed and provides a method-specific reference
                
            
    
    The Elecsys Anti-HBe (hepatitis B e antibody) assay will be performed on the fully automated cobas e 801 electrochemiluminescence immunoassay analyzer. During the first incubation, anti-HBe present in the patient's sample binds to the added HBe antigen (HBeAg). In the second incubation, the still-free binding sites on the HBeAg become occupied after addition of biotinylated antibodies and ruthenium complex-labeled antibodies specific for HBeAg, together with streptavidin-coated microparticles. The entire complex becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are then washed away, and application of a voltage to the electrode then induces chemiluminescent emission, which is measured by a photomultiplier. Test result for each patient's sample is determined automatically by the assay-specific software program by comparing the electrochemiluminescence signal obtained from the sample with the cutoff index value set from reagent lot-specific assay calibrations.(Elecsys Anti-HBe. Roche Diagnostics; v1.0, 12/2021)
    
    
        PDF Report
            
                
                
                    
                    Indicates whether the report includes an additional document with charts, images or other enriched information
                
            
    
    
    
        Day(s) Performed
            
                
                
                    
                    Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
                
            
    
    Monday through Friday, Sunday
    
        Report Available
            
                
                
                    
                    The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
                
            
    
    
    
        Specimen Retention Time
            
                
                
                    
                    Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
                
            
    
    
    
        Performing Laboratory Location
            
                
                
                    
                    Indicates the location of the laboratory that performs the test
                
            
    
    
    
        Fees :
            
                
                
                    
                    Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
                
            
    
    - Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
    
        Test Classification
            
                
                
                    
                    Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
                
            
    
    This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.
    
        CPT Code Information
            
                
                
                    
                    Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
                
            
    
    CPT codes are provided by the performing laboratory.
86707
    
        LOINC® Information
            
                
                
                    
                    Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
                
            
    
    | Test Id | Test Order Name | Order LOINC Value | 
|---|---|---|
| HEAB | HBe Antibody, S | 33463-1 | 
| Result Id | Test Result Name | Result LOINC Value 
                                        
                                        Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
                                     | 
|---|---|---|
| HEAB | HBe Antibody, S | 33463-1 |