Test Id : LLPT
Leukemia/Lymphoma Immunophenotyping, Flow Cytometry, Tissue
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Evaluation of tissues for potential involvement by:
-Chronic lymphoproliferative disorders
-Malignant lymphomas
-Acute lymphoblastic leukemia
-Acute myelogenous leukemia
    
        Reflex Tests
            
                
                
                    
                    Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.
                
            
    
    | Test Id | Reporting Name | Available Separately | Always Performed | 
|---|---|---|---|
| FCINT | Flow Cytometry Interp, 2-8 Markers | No, (Bill Only) | No | 
| FCIMS | Flow Cytometry Interp, 9-15 Markers | No, (Bill Only) | No | 
| FCINS | Flow Cytometry Interp,16 or greater | No, (Bill Only) | No | 
    
        Additional Tests
            
                
                
                    
                    Lists tests that are always performed, at an additional charge, with the initial tests.
                
            
    
    | Test Id | Reporting Name | Available Separately | Always Performed | 
|---|---|---|---|
| FIRST | Flow Cytometry, Cell Surface, First | No, (Bill Only) | Yes | 
| ADD1 | Flow Cytometry, Cell Surface, Addl | No, (Bill Only) | Yes | 
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    When this test is ordered, a screening panel and a professional interpretation will always be charged. The screening panel will be charged based on number of makers tested (FIRST for first marker, ADD1 for each additional marker). The interpretation will be set based on markers tested in increments of 9 to 15, or 16 and greater. In addition, reflex testing may occur to fully characterize a disease state or clarify any abnormalities from the screening test. Reflex tests will be performed at an additional charge for each marker tested (FIRST if applicable, ADD1 if applicable).
 
The tissue panel is initially performed to evaluate for monotypic B cells by kappa and lambda immunoglobulin light chain expression, CD5, CD10, CD19, CD20, and CD23.Increased numbers of blasts and plasma cells are identified by CD45 expression along with side scatter gating. The panel can also evaluate T cells with CD3, CD5, and CD7. Additionally, viability is assessed on all tissue specimens using 7-AAD (7-amino actinomycin d) exclusion.
 
This panel, together with the provided clinical history and morphologic review is used to determine what, if any, further testing is needed for disease diagnosis or classification. If additional testing is required, it will be added per algorithm to fully characterize a disease state with a charge per unique antibody tested.
 
In addition to reflexing flow cytometric panels, fluorescence in situ hybridization (FISH), molecular testing or cytochemical stains may be recommended by the Mayo Clinic pathologist to facilitate diagnosis. They will contact the referring provider or pathologist to confirm the addition of these tests.
If no abnormalities are detected by the initial panel, no further flow cytometric assessment will be performed unless otherwise indicated by specific features of the clinical presentation or prior laboratory results.
    
        Method Name
            
                
                
                    
                    A short description of the method used to perform the test
                
            
    
    Immunophenotyping
    
        NY State Available
            
                
                
                    
                    Indicates the status of NY State approval and if the test is orderable for NY State clients.
                
            
    
    
    
        Reporting Name
            
                
                
                    
                    Lists a shorter or abbreviated version of the Published Name for a test
                
            
    
    
    
        Aliases
            
                
                
                    
                    Lists additional common names for a test, as an aid in searching
                
            
    
    Flow Cytometry, Tissue
Leukemia Immunophenotyping, Tissue Panel
Lymphoma Immunophenotyping by Flow Cytometry
Lymphoma Immunophenotyping, Tissue
Tissue Panel, Leukemia Immunophenotyping
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    When this test is ordered, a screening panel and a professional interpretation will always be charged. The screening panel will be charged based on number of makers tested (FIRST for first marker, ADD1 for each additional marker). The interpretation will be set based on markers tested in increments of 9 to 15, or 16 and greater. In addition, reflex testing may occur to fully characterize a disease state or clarify any abnormalities from the screening test. Reflex tests will be performed at an additional charge for each marker tested (FIRST if applicable, ADD1 if applicable).
 
The tissue panel is initially performed to evaluate for monotypic B cells by kappa and lambda immunoglobulin light chain expression, CD5, CD10, CD19, CD20, and CD23.Increased numbers of blasts and plasma cells are identified by CD45 expression along with side scatter gating. The panel can also evaluate T cells with CD3, CD5, and CD7. Additionally, viability is assessed on all tissue specimens using 7-AAD (7-amino actinomycin d) exclusion.
 
This panel, together with the provided clinical history and morphologic review is used to determine what, if any, further testing is needed for disease diagnosis or classification. If additional testing is required, it will be added per algorithm to fully characterize a disease state with a charge per unique antibody tested.
 
In addition to reflexing flow cytometric panels, fluorescence in situ hybridization (FISH), molecular testing or cytochemical stains may be recommended by the Mayo Clinic pathologist to facilitate diagnosis. They will contact the referring provider or pathologist to confirm the addition of these tests.
If no abnormalities are detected by the initial panel, no further flow cytometric assessment will be performed unless otherwise indicated by specific features of the clinical presentation or prior laboratory results.
    
        Specimen Type
            
                
                
                    
                    Describes the specimen type validated for testing
                
            
    
        Tissue
    
        Ordering Guidance
    
    Order LCMS / Leukemia/Lymphoma Immunophenotyping, Flow Cytometry, Varies if the specimen is a fresh (less than 4 days post-collection), unfixed, non-embedded bone marrow core biopsy, bone or bone lesion. This is an equivalent source for bone marrow aspirate only in the event of a dry tap during the bone marrow harvesting procedure. Indicate “dry tap" in performing lab notes or paperwork when submitting this specimen type.
This test is not intended for product of conception (POC) specimens. For POC specimens see CMAPC / Chromosomal Microarray, Autopsy, Products of Conception, or Stillbirth.
    
        Shipping Instructions
    
    Specimen must arrive within 4 days of collection.
    
        Necessary Information
    
    The following information is required:
1. Pertinent clinical history, including reason for testing or clinical indication/morphologic suspicion
2. Provide the following:
-Tissue type
-Location
-Pathology/diagnostic report, including the client surgical pathology case number
    
        Specimen Required
            
                
                
                    
                    Defines the optimal specimen required to perform the test and the preferred volume to complete testing
                
            
    
    Submit 1 of the following specimens:
Preferred
Specimen Type: Tissue
Supplies: Hank's Solution (T132)
Container/Tube: Sterile container with 15 mL of tissue culture medium (eg, Hank's balanced salt solution, RPMI, or equivalent)
Specimen Volume: 5 mm(3) or larger biopsy
Collection Instructions:
1. Place tissue into a sterile container with 15 mL of tissue culture medium (eg, Hank's balanced salt solution, RPMI, or equivalent).
2. Send intact specimen (do not mince)
3. Specimen cannot be fixed.
Specimen Stability Information: Ambient 4 days/Refrigerated 4 days
Acceptable
Specimen Type: Fine needle aspirate (FNA)
Supplies: Hank's Solution (T132)
Container/Tube: Sterile container with 15 mL of tissue culture medium (eg, Hank's balanced salt solution, RPMI, or equivalent)
Specimen Volume: Entire collection
Collection Instructions:
1. Collect FNA and transfer entire collection into a sterile container with 15 mL of tissue culture medium (eg, Hank's balanced salt solution, RPMI, or equivalent).
2. Send intact specimen (do not mince)
3. Specimen cannot be fixed.
Specimen Stability Information: Ambient 4 days/Refrigerated 4 days
    
        Special Instructions
            
                
                
                    
                    Library of PDFs including pertinent information and forms related to the test
                
            
    
    
            
    
        Forms
    
    1. Hematopathology Patient Information (T676)
2. If not ordering electronically, complete, print, and send a Hematopathology/Cytogenetics Test Request (T726) with the specimen.
    
        Specimen Minimum Volume
            
                
                
                    
                    Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
                
            
    
    1 mm(3)
    
        Reject Due To
            
                
                
                    
                    Identifies specimen types and conditions that may cause the specimen to be rejected
                
            
    
    | Fixed or paraffin-embedded tissue | Reject | 
| Minced tissue | Reject | 
| Dry tissue without transport medium | Reject | 
    
        Specimen Stability Information
            
                
                
                    
                    Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
                
            
    
    | Specimen Type | Temperature | Time | Special Container | 
|---|---|---|---|
| Tissue | Refrigerated (preferred) | ||
| Ambient | |||
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Evaluation of tissues for potential involvement by:
-Chronic lymphoproliferative disorders
-Malignant lymphomas
-Acute lymphoblastic leukemia
-Acute myelogenous leukemia
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    When this test is ordered, a screening panel and a professional interpretation will always be charged. The screening panel will be charged based on number of makers tested (FIRST for first marker, ADD1 for each additional marker). The interpretation will be set based on markers tested in increments of 9 to 15, or 16 and greater. In addition, reflex testing may occur to fully characterize a disease state or clarify any abnormalities from the screening test. Reflex tests will be performed at an additional charge for each marker tested (FIRST if applicable, ADD1 if applicable).
 
The tissue panel is initially performed to evaluate for monotypic B cells by kappa and lambda immunoglobulin light chain expression, CD5, CD10, CD19, CD20, and CD23.Increased numbers of blasts and plasma cells are identified by CD45 expression along with side scatter gating. The panel can also evaluate T cells with CD3, CD5, and CD7. Additionally, viability is assessed on all tissue specimens using 7-AAD (7-amino actinomycin d) exclusion.
 
This panel, together with the provided clinical history and morphologic review is used to determine what, if any, further testing is needed for disease diagnosis or classification. If additional testing is required, it will be added per algorithm to fully characterize a disease state with a charge per unique antibody tested.
 
In addition to reflexing flow cytometric panels, fluorescence in situ hybridization (FISH), molecular testing or cytochemical stains may be recommended by the Mayo Clinic pathologist to facilitate diagnosis. They will contact the referring provider or pathologist to confirm the addition of these tests.
If no abnormalities are detected by the initial panel, no further flow cytometric assessment will be performed unless otherwise indicated by specific features of the clinical presentation or prior laboratory results.
    
        Clinical Information
            
                
                
                    
                    Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
                
            
    
    Cellular immunophenotyping, characterizing cells by using antibodies directed against cell surface markers, is generally regarded as a fundamental element in establishing a diagnosis of tissue involvement by hematolymphoid malignancies, when used in conjunction with morphologic assessment. It is also an essential component in subclassification of hematolymphoid malignancies when present.
    
        Reference Values
            
                
                
                    
                    Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
                
            
    
    An interpretive report will be provided.
    
        Interpretation
            
                
                
                    
                    Provides information to assist in interpretation of the test results
                
            
    
    This test will be processed as a laboratory consultation. An interpretation of the immunophenotypic findings and correlation with the morphologic features will be provided by a hematopathologist for every case.
Normal tissues typically contain a mixture of B cells with polytypic surface immunoglobulin light chain expression and T cells with unremarkable expression of the T cell-associated antigens CD3, CD5, and CD7. Typically, no appreciable blast population is present by CD45 and side scatter analysis.
    
        Cautions
            
                
                
                    
                    Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances
                
            
    
    It is well recognized that a negative flow cytometry result does not exclude tissue involvement by hematolymphoid malignancy. This may be attributable to sampling bias, although some malignancies, such as Hodgkin lymphoma, are not detected by this technique.
 
Viability will be assessed in all tissue specimens. Cases in which the viability is low (<50%) are prone to false-negative results and, therefore, must be interpreted with caution. In cases with viability less than 50%, testing will be attempted but may not be interpretable. Fine-needle aspiration and small biopsy specimens have a higher frequency of low cell counts and poor viability, which may be uninterpretable.
 
Even when abnormal, in most instances the results of flow cytometry are insufficient for complete subclassification of a hematolymphoid malignancy. Precise subclassification requires correlation with the histopathologic features in paraffin-embedded materials and also, in some instances, the results of cytogenetic analyses.
 
The tissue used for flow cytometry cannot be subsequently submitted for histopathologic evaluation. For this reason, this technique should be avoided in small biopsy specimens.
    
        Clinical Reference
            
                
                
                    
                    Recommendations for in-depth reading of a clinical nature
                
            
    
    1. Morice WG, Hodnefield JM, Kurtin PJ, Hanson CA. An unusual case of leukemic mantle cell lymphoma with a blastoid component showing loss of CD5 and aberrant expression of CD10. Am J Clin Pathol. 2004;122(1):122-127
2. Hanson CA. Acute leukemias and myelodysplastic syndromes. In: McClatchey KD, ed. Clinical Laboratory Medicine. Williams and Wilkins; 1994:939-969
3. Jaffe ES, Cossman J. Immunodiagnosis of lymphoid and mononuclear phagocytic neoplasms. In: Rose NR, Friedman H, Fahey JL, eds. Manual of Clinical Immunology. 3rd ed. ASM Press; 1987:779-790
4. Witzig TE, Banks PM, Stenson MJ, et al. Rapid immunotyping of B-cell non-Hodgkin's lymphomas by flow cytometry. A comparison with the standard frozen-section method. Am J Clin Pathol. 1990;94(3):280-286
5. Jevremovic D, Dronca RS, Morice WG, et al. CD5+ B-cell lymphoproliferative disorders: Beyond chronic lymphocytic leukemia and mantle cell lymphoma. Leuk Res. 2010;34(9):1235-1238
6. Jevremovic D, Olteanu H. Flow cytometry applications in the diagnosis of T/NK-cell lymphoproliferative disorders. Cytometry B Clin Cytom. 2019;96(2):99-115
7. Shi M, Jevremovic D, Otteson GE, Timm MM, Olteanu H, Horna P. Single antibody detection of T-Cell receptor alpha beta clonality by flow cytometry rapidly identifies mature T-Cell neoplasms and monotypic small CD8-positive subsets of uncertain significance. Cytometry B Clin Cytom. 2020;98(1):99-107
    
        Method Description
            
                
                
                    
                    Describes how the test is performed and provides a method-specific reference
                
            
    
    Flow cytometric immunophenotyping of tissues is performed using the following antibodies:
Tissue Panel: CD3, CD5, CD7, CD10, CD19, CD20, CD23, CD45, 7-AAD, and kappa and lambda immunoglobulin light chains.
 
Possible Additional Panels: Performed per algorithmic approach:
 
T-cell Panel: CD2, CD3, CD4, CD5, CD7, CD8, CD45, TRBC1, and gamma/delta
 
Acute Panel: CD2, CD3, CD5, CD7, CD13, CD15, CD16, CD19, CD20, CD33, CD34, CD36, CD38, CD45, CD56, CD64, CD117, and HLA-DR
 
Myeloperoxidase (MPO)/terminal deoxynucleotidyl transferase (TdT) (MPO/TdT) Panel: cytoplasmic CD3, CD13, cytoplasmic CD22, CD34, CD45, cytoplasmic CD79a, nuclear TDT, and cytoplasmic MPO
 
Plasma Cell Panel: CD19, CD38, CD45, CD138, and cytoplasmic kappa and lambda immunoglobulin light chains.(Keren P, McCoy JP, Carey J, eds. Flow Cytometry in Clinical Diagnosis. 4th ed. ASCP Press; 2007; Betters DM: Use of flow cytometry in clinical practice. J Adv Pract Oncol. 2015;6[5]:435-440)
    
        PDF Report
            
                
                
                    
                    Indicates whether the report includes an additional document with charts, images or other enriched information
                
            
    
    
    
        Day(s) Performed
            
                
                
                    
                    Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
                
            
    
    Monday through Saturday
    
        Report Available
            
                
                
                    
                    The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
                
            
    
    
    
        Specimen Retention Time
            
                
                
                    
                    Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
                
            
    
    
    
        Performing Laboratory Location
            
                
                
                    
                    Indicates the location of the laboratory that performs the test
                
            
    
    
    
        Fees :
            
                
                
                    
                    Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
                
            
    
    - Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
    
        Test Classification
            
                
                
                    
                    Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
                
            
    
    This test was developed using an analyte specific reagent. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.
    
        CPT Code Information
            
                
                
                    
                    Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
                
            
    
    CPT codes are provided by the performing laboratory.
88184-Flow cytometry; first cell surface, cytoplasmic or nuclear marker x 1
88185-Flow cytometry; additional cell surface, cytoplasmic or nuclear marker (each)
88187-Flow Cytometry Interpretation, 2 to 8 Markers (if appropriate)
88188-Flow Cytometry Interpretation, 9 to 15 Markers (if appropriate)
88189-Flow Cytometry Interpretation, 16 or More Markers (if appropriate)
    
        LOINC® Information
            
                
                
                    
                    Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
                
            
    
    | Test Id | Test Order Name | Order LOINC Value | 
|---|---|---|
| LLPT | Leukemia Lymphoma Phenotype, Tissue | In Process | 
| Result Id | Test Result Name | Result LOINC Value 
                                        
                                        Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
                                     | 
|---|---|---|
| 19562 | Accession Number | 57723-9 | 
| 19569 | Material: | 81178-6 | 
| 19568 | Specimen: | 31208-2 | 
| 19574 | Final Diagnosis: | 34574-4 | 
| 19563 | Referring Pathologist/Physician | 46608-6 | 
| 19564 | Ref Path/Phys Address | 74221-3 | 
| 19565 | Place of Death: | 21987-3 | 
| 19566 | Date and Time of Death: | 81956-5 | 
| 19567 | Date of Autopsy: | 75711-2 | 
| 19570 | Tissue Discription: | 22634-0 | 
| 19572 | Clinical History: | 22636-5 | 
| 19576 | Revision Description: | 81317-0 | 
| 19577 | Signing Pathologist: | 19139-5 | 
| 19578 | Special Procedures: | 30954-2 | 
| 19579 | SP Signing Pathologist: | 19139-5 | 
| 19580 | *Previous Report Follows* | 22639-9 | 
| 19581 | Addendum: | 35265-8 | 
| 19582 | Addendum Comment: | 22638-1 | 
| 19583 | Addendum Pathologist: | 19139-5 | 
| 19571 | Microscopic Description | 22635-7 | 
| 19573 | Final Diagnosis: | 34574-4 | 
| 19575 | Special Studies | 30954-2 | 
| CK139 | LLPT Result | No LOINC Needed |