Test Id : HCVDX
Hepatitis C Virus (HCV) Antibody with Reflex to HCV RNA, PCR, Symptomatic, Serum
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Diagnosis of recent or chronic hepatitis C virus (HCV) infection in symptomatic patients
This test should not be used as a screening or confirmatory test for hepatitis C in blood or human cells/tissue donors.
This test profile is not useful for detection or diagnosis of acute hepatitis C, since HCV antibodies may not be detectable until after 2 months following exposure and HCV RNA testing is not performed on specimens with negative HCV antibody screening test results.
    
        Highlights
    
    This diagnostic test is indicated for testing symptomatic individuals that may or may not have risk factors for a hepatitis C virus infection.
    
        Reflex Tests
            
                
                
                    
                    Lists tests that may or may not be performed, at an additional charge, depending on the result and interpretation of the initial tests.
                
            
    
    | Test Id | Reporting Name | Available Separately | Always Performed | 
|---|---|---|---|
| HCVQN | HCV RNA Detect/Quant, S | Yes | No | 
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    If hepatitis C virus (HCV) antibody screen is reactive, then HCV RNA by reverse transcription polymerase chain reaction will be performed at an additional charge.
For more information see Hepatitis C: Testing Algorithm for Screening and Diagnosis.
    
        Method Name
            
                
                
                    
                    A short description of the method used to perform the test
                
            
    
    Electrochemiluminescence Immunoassay (ECLIA)
    
        NY State Available
            
                
                
                    
                    Indicates the status of NY State approval and if the test is orderable for NY State clients.
                
            
    
    
    
        Reporting Name
            
                
                
                    
                    Lists a shorter or abbreviated version of the Published Name for a test
                
            
    
    
    
        Aliases
            
                
                
                    
                    Lists additional common names for a test, as an aid in searching
                
            
    
    Anti-HCV (Hepatitis C Virus)
HCV (Hepatitis C Virus) Antibody
HCV Antibody
Hepatitis C
Non-A, Non-B Hepatitis
Hepatitis C Ab
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    If hepatitis C virus (HCV) antibody screen is reactive, then HCV RNA by reverse transcription polymerase chain reaction will be performed at an additional charge.
For more information see Hepatitis C: Testing Algorithm for Screening and Diagnosis.
    
        Specimen Type
            
                
                
                    
                    Describes the specimen type validated for testing
                
            
    
        Serum SST
    
        Ordering Guidance
    
    This test is not intended for testing asymptomatic individuals (ie, screening purposes). For testing such patients with or without risk factors for hepatitis C virus (HCV) infection, order HCSRN / Hepatitis C Virus (HCV) Antibody Screen with Reflex to HCV RNA, PCR, Asymptomatic, Serum.
 
For testing autopsy/cadaver or hemolyzed specimens, order HCCAD / Hepatitis C Virus Antibody Screen for Cadaveric or Hemolyzed Specimens, Asymptomatic, Serum for asymptomatic individuals or HCCDD / Hepatitis C Virus Antibody in Cadaveric or Hemolyzed Specimens, Symptomatic, Serum for symptomatic individuals.
 
For patients with acute or recent HCV infections (<3 months from time of exposure) or who are repeatedly reactive by screening tests and should be confirmed by a more HCV-specific test, order HCVQN / Hepatitis C Virus (HCV) RNA Detection and Quantification by Real-Time Reverse Transcription-PCR, Serum.
If testing is desired to distinguish between true positivity and biologic false positivity for HCV antibody, then testing may be done with a second HCV antibody assay approved by the US Food and Drug Administration for diagnosis of HCV infection that is different from the assay used for initial antibody testing (HCCAD / Hepatitis C Virus Antibody Screen for Cadaveric or Hemolyzed Specimens, Asymptomatic, Serum).
    
        Shipping Instructions
    
    If shipment will be delayed for more than 24 hours, freeze serum at -70 degrees C until shipment and transport on dry ice.
    
        Necessary Information
    
    Date of collection is required.
    
        Specimen Required
            
                
                
                    
                    Defines the optimal specimen required to perform the test and the preferred volume to complete testing
                
            
    
    Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1.3 mL
Collection Instructions:
1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot serum into plastic vial.
    
        Special Instructions
            
                
                
                    
                    Library of PDFs including pertinent information and forms related to the test
                
            
    
    
            
    
        Forms
    
    If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-Kidney Transplant Test Request
    
        Specimen Minimum Volume
            
                
                
                    
                    Defines the amount of sample necessary to provide a clinically relevant result as determined by the testing laboratory. The minimum volume is sufficient for one attempt at testing.
                
            
    
    0.9 mL
    
        Reject Due To
            
                
                
                    
                    Identifies specimen types and conditions that may cause the specimen to be rejected
                
            
    
    | Gross hemolysis | Reject | 
| Gross lipemia | Reject | 
| Gross icterus | Reject | 
    
        Specimen Stability Information
            
                
                
                    
                    Provides a description of the temperatures required to transport a specimen to the performing laboratory, alternate acceptable temperatures are also included
                
            
    
    | Specimen Type | Temperature | Time | Special Container | 
|---|---|---|---|
| Serum SST | Frozen (preferred) | 84 days | |
| Refrigerated | 6 days | 
    
        Useful For
            
                
                
                    
                    Suggests clinical disorders or settings where the test may be helpful
                
            
    
    Diagnosis of recent or chronic hepatitis C virus (HCV) infection in symptomatic patients
This test should not be used as a screening or confirmatory test for hepatitis C in blood or human cells/tissue donors.
This test profile is not useful for detection or diagnosis of acute hepatitis C, since HCV antibodies may not be detectable until after 2 months following exposure and HCV RNA testing is not performed on specimens with negative HCV antibody screening test results.
    
        Testing Algorithm
            
                
                
                    
                    Delineates situations when tests are added to the initial order. This includes reflex and additional tests.
                
            
    
    If hepatitis C virus (HCV) antibody screen is reactive, then HCV RNA by reverse transcription polymerase chain reaction will be performed at an additional charge.
For more information see Hepatitis C: Testing Algorithm for Screening and Diagnosis.
    
        Clinical Information
            
                
                
                    
                    Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
                
            
    
    Hepatitis C virus (HCV) is recognized as the cause of most cases of posttransfusion hepatitis and is a significant cause of morbidity and mortality worldwide. In the United States, HCV infection is quite common, with an estimated 2.4 million chronically HCV-infected individuals.
 
Laboratory testing for HCV infection usually begins by screening for the presence of HCV-specific antibodies in serum, using an US Food and Drug Administration-approved screening test. Specimens that are repeatedly reactive by screening tests should be confirmed with HCV tests with higher specificity, such as direct detection of HCV RNA by reverse transcription polymerase chain reaction or HCV-specific antibody confirmatory tests.
 
Hepatitis C virus antibodies are usually not detectable during the first 2 months following infection, but they are usually detectable by the late convalescent stage (>6 months after onset) of infection. These antibodies do not neutralize the virus and they do not provide immunity against this viral infection.
 
Current screening serologic tests to detect antibodies to HCV include enzyme immunoassay and chemiluminescence immunoassay.
 
Despite the value of serologic tests to screen for HCV infection, several limitations of serologic testing exist:
-There may be a long delay (up to 6 months) between exposure to the virus and the development of detectable HCV-specific antibodies in immunocompromised individuals
-False-reactive screening test result can occur
-A reactive screening test result does not distinguish between past (resolved) and present HCV infection
-Serologic tests cannot provide information on clinical response to anti-HCV therapy
 
Reactive screening test results should be followed by a supplemental or confirmatory test, such as nucleic acid test for HCV RNA or HCV antibody confirmatory test. Nucleic acid tests provide a very sensitive and specific approach for the direct detection of HCV RNA.
 
For more information see Hepatitis C: Testing Algorithm for Screening and Diagnosis.
    
        Reference Values
            
                
                
                    
                    Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
                
            
    
    Negative
For more information see Viral Hepatitis Serologic Profiles
    
        Interpretation
            
                
                
                    
                    Provides information to assist in interpretation of the test results
                
            
    
    Reactive hepatitis C virus (HCV) antibody screening results with cutoff index (COI) values less than or equal to 20.0 with this assay are not predictive of the true HCV antibody status. Additional testing is available to confirm HCV antibody status.
 
Reactive results with COI values of greater than 20.0 with this assay are highly predictive (95% or greater probability) of the true HCV antibody status, but additional testing is needed to differentiate between past (resolved) and chronic hepatitis C. Based on Centers for Disease Control and Prevention recommendations, reactive HCV antibody screen results should be followed by HCV RNA testing (HCVQN / Hepatitis C Virus (HCV) RNA Detection and Quantification by Real-Time Reverse Transcription-PCR, Serum). Detection of HCV RNA indicates current HCV infection. If HCV RNA is not detected, that indicates either past, resolved HCV infection, or false HCV antibody positivity.
 
A negative screening test result does not exclude the possibility of exposure to or infection with HCV. Negative screening test results in individuals with prior exposure to HCV may be due to low antibody levels that are below the limit of detection of this assay or lack of reactivity to the HCV antigens used in this assay. Patients with acute or recent HCV infections (<2 months from time of exposure) may have false-negative HCV antibody results due to the time needed for seroconversion (average of 8 to 9 weeks). Testing for HCV RNA using HCVQN / Hepatitis C Virus (HCV) RNA Detection and Quantification by Real-Time Reverse Transcription-PCR, Serum is necessary for detection of HCV infection in such patients.
    
        Cautions
            
                
                
                    
                    Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances
                
            
    
    This assay is not licensed by the US Food and Drug Administration for the screening of blood, plasma, and tissue donors.
 
For diagnostic purposes, results should always be assessed in conjunction with the patient's medical history, clinical examination, and other findings.
 
A reactive hepatitis C antibody (anti-HCV) result does not exclude co-infection by another hepatitis virus.
 
False positive results due to non-specific reactivity cannot be ruled out with the Elecsys Anti-HCV II assay. In rare cases, interference due to extremely high titers of antibodies to streptavidin or ruthenium can occur, causing false-reactive anti-HCV results.
 
Infants born to HCV-infected mothers may have false-reactive HCV antibody test results due to transplacental passage of maternal HCV IgG antibodies. HCV antibody testing is not recommended until at least 18 months in these infants.
 
A single negative hepatitis C virus (HCV) RNA test result together with a reactive anti-HCV screen result with a cutoff index value greater than 20.0 does not rule out the possibility of chronic HCV infection. Repeat testing for HCV RNA in 1 to 2 months is recommended in patient at risk for chronic hepatitis C.
 
Serum specimens from individuals taking biotin supplements at 20 mg or more per day may have false-negative HCV antibody test results with this assay due to interference of biotin. Such individuals should stop taking these biotin-containing dietary supplements for a minimum 12 hours before blood collection for this test.
 
Negative anti-HCV test results from immunosuppressed individuals should be interpreted with caution.
 
Results obtained with the Elecsys Anti-HCV II assay may not be used interchangeably with values obtained with different manufacturers' assay methods.
 
Assay performance characteristics have not been established for the following specimen characteristics or specimen types:
-Grossly icteric (total bilirubin level of >66 mg/dL)
-Grossly lipemic (intralipid level of >2000 mg/dL)
-Grossly hemolyzed (hemoglobin level of >1000 mg/dL)
-Biotin level >1200 ng/mL
-Rheumatoid factor level >1200 IU/mL
-Albumin level >7 g/dL
-IgA level >1600 mg/dL
-IgG level >7000 mg/dL
-IgM level >1000 mg/dL
-Presence of particulate matter
-Cadaveric specimens
-Specimen types other than serum
    
        Clinical Reference
            
                
                
                    
                    Recommendations for in-depth reading of a clinical nature
                
            
    
    1. Centers for Disease Control and Prevention (CDC). Testing for HCV infection: an update of guidance for clinicians and laboratorians. Morb Mortal Wkly Rep. 2013;62(18):362-365
2. Schillie S, Wester C, Osborne M, Wesolowski L, Ryerson AB. CDC Recommendations for hepatitis C screening among adults - United States, 2020. MMWR Recomm Rep. 2020;69(2):1-17
3. Chou R, Dana T, Fu R, et al. Screening for hepatitis C virus infection in adolescents and adults: updated evidence report and systematic review for the U.S. Preventive Services Task Force. JAMA. 2020;323(10):976-991
4. American Association for the Study of Liver Diseases and Infectious Diseases Society of America: HCV guidance: Recommendations for testing, managing, and treating hepatitis C. Updated October 24, 2022. Accessed August 12, 2024. Available at www.hcvguidelines.org/evaluate/testing-and-linkage
    
        Method Description
            
                
                
                    
                    Describes how the test is performed and provides a method-specific reference
                
            
    
    The Elecsys Anti-HCV (hepatitis C virus) II assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HCV-specific antibodies present in the patient’s sample react with biotinylated HCV-specific antigens and a reagent containing HCV-specific antigens labeled with a ruthenium complex to form sandwich complexes. After addition of streptavidin-coated microparticles (solid phase), these complexes bind to the solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode.  Unbound substances are then washed away and voltage is applied to the electrode which induces chemiluminescent emissions that are measured by a photomultiplier. Test result is determined by comparing the electrochemiluminescence signal generated from the patient’s sample to the cutoff index value set from reagent lot-specific assay calibration. (Package insert: Elecsys Anti-HCV II. Roche Diagnostics; v1.0, 03/2023)
    
        PDF Report
            
                
                
                    
                    Indicates whether the report includes an additional document with charts, images or other enriched information
                
            
    
    
    
        Day(s) Performed
            
                
                
                    
                    Outlines the days the test is performed. This field reflects the day that the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time before the test is performed. Some tests are listed as continuously performed, which means that assays are performed multiple times during the day.
                
            
    
    Monday through Saturday
    
        Report Available
            
                
                
                    
                    The interval of time (receipt of sample at Mayo Clinic Laboratories to results available) taking into account standard setup days and weekends. The first day is the time that it typically takes for a result to be available. The last day is the time it might take, accounting for any necessary repeated testing.
                
            
    
    
    
        Specimen Retention Time
            
                
                
                    
                    Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
                
            
    
    
    
        Performing Laboratory Location
            
                
                
                    
                    Indicates the location of the laboratory that performs the test
                
            
    
    
    
        Fees :
            
                
                
                    
                    Several factors determine the fee charged to perform a test. Contact your U.S. or International Regional Manager for information about establishing a fee schedule or to learn more about resources to optimize test selection.
                
            
    
    - Authorized users can sign in to Test Prices for detailed fee information.
- Clients without access to Test Prices can contact Customer Service 24 hours a day, seven days a week.
- Prospective clients should contact their account representative. For assistance, contact Customer Service.
    
        Test Classification
            
                
                
                    
                    Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR) product.
                
            
    
    This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.
    
        CPT Code Information
            
                
                
                    
                    Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Clinic Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
CPT codes are provided by the performing laboratory.
                
            
    
    CPT codes are provided by the performing laboratory.
86803
87522 (if appropriate)
    
        LOINC® Information
            
                
                
                    
                    Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the order and results codes of this test. LOINC values are provided by the performing laboratory.
                
            
    
    | Test Id | Test Order Name | Order LOINC Value | 
|---|---|---|
| HCVDX | HCV Ab w/Reflex to HCV PCR, S | 40726-2 | 
| Result Id | Test Result Name | Result LOINC Value 
                                        
                                        Applies only to results expressed in units of measure originally reported by the performing laboratory. These values do not apply to results that are converted to other units of measure.
                                     | 
|---|---|---|
| HCVA4 | HCV Ab, S | 40726-2 |