Web: | mayocliniclabs.com |
---|---|
Email: | mcl@mayo.edu |
Telephone: | 800-533-1710 |
International: | +1 855-379-3115 |
Values are valid only on day of printing. |
24-Hour volume is required.
Patient Preparation: High concentrations of gadolinium and iodine are known to interfere with most metals tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies: Urine Tubes, 10 mL (T068)
Container/Tube: Plastic, 10-mL urine tube or clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 3 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. Refrigerate specimen within 4 hours of completion of 24-hour collection.
3. See Trace Metals Analysis Specimen Collection and Transport in Special Instructions for complete instructions.
Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens in Special Instructions for multiple collections.
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.
Note: The addition of preservative or application of temperature controls must occur within 4 hours of completion of the collection.
Ambient | OK |
Refrigerate | Preferred |
Frozen | OK |
50% Acetic Acid | No |
Boric Acid | No |
Diazolidinyl Urea | No |
6M Hydrochloric Acid | OK |
6M Nitric Acid | OK |
Sodium Carbonate | No |
Thymol | No |
Toluene | No |
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |